Ul roof assemblies USG Ceiling Technix™ Quickly design and specify complex ceilings using lean USG families you can trust with our Ceilings Family Revit® Plugin. 21) Edge systems used with low-slope roofing systems (ANSI/SPRI ES-1) Fire Tests of Roof Coverings - spread of flame, intermittent flaming, burning brand (UL 790/ASTM E108) Fire-resistance rated assemblies and rating certifications. fastened metal roof deck panel assembly. MONOKOTE® MK-6/HY Product Data Sheet. Feb 9, 2021 · codes commonly require floor/ceiling and wall assem-blies to be fire-resistance rated in accordance with standard fire tests. UL . OC along each truss. ix. See Fire Resistance Directory — Metal Roof Deck Panels (CETW). Throughout North America and in many other regions, the fire resistance assembly ratings are determined based on fire tests of full-scale floor-ceiling or roof-ceiling assemblies (approximately 14 ft by 17-1/2 ft) conducted in accordance with UL 263, the Standard for Fire Tests of Building Construction and Materials (ASTM E119, ULC S101). com | North America Customer Service: +1 (877) 423 6491 GCP Applied Technologies Inc. The details of the each design assembly are listed on UL Online Certification Directory www. To obtain a UL 790 fire classification, roof assemblies are required to pass a series of exterior fire exposure tests – the Class A tests are more severe than the Class B tests, which are more severe than the Class C tests. 6d ringed shank nails spaced 12 in. Most roof insulation assemblies are tested with a Class C roofing material covering the assembly. ASSEMBLIES. ul. proprietary materials as listed in UL fire resistance ratings. Overall Thickness. Main Runners, Cross Tees, Cross Channels and Wall Angle as Listed Below (UL Type DGL):; Suspension System May be Used in Lieu of the Resilient Channels. Our testing services assess compliance to the following UL Solutions and industry standards: Dynamic wind uplift resistance of membrane -roofing systems (CSA A123. UL 580 Standard for Tests for Uplift Resistance of Roof Assemblies. (min size) polyisocyanurate foamed plastic insulation boards applied in one or more layers. Have a Question About Assemblies? Call: 1-800-USG-4YOU Jun 21, 2024 · ul x795 pdf dwg x795 all na na na na na gcpat. grade "C-D" or "Sheathing". 3. thick wood structural panels secured to trusses with No. Refer to Fire-resistance Rated Assemblies – ANSI/UL 263 in UL Product iQ for information about an assembly that meets your project specifications. Jun 21, 2024 · MONOKOTE products: UL Designs & Thickness — Roof Assemblies. Nom 15/32 in. Here, you can find drawings for our UL fire-rated floor assemblies and UL fire-rated ceiling assemblies. Helpful documents and resources for CGC’s roof assemblies can be found on this page. Refer to our roof-ceiling assembly documents, which includes UL fire-rated roof assemblies, for easy guidance through the assembly of a roof or ceiling on your next project. elements of buildings, the fire-resistance rating classifies the ability of an assembly to confine and isolate fire within a zone comprised of fire-resistance rated walls, ceiling and floor assemblies. Loosely laid, adhered or mechanically fastened to the Gypsum Sheathing and Structural Cement-Fiber Aug 9, 2019 · UL 263 states “Floor-ceiling and roof-ceiling assemblies and individual beams in buildings should be considered restrained when the surrounding or supporting structure is capable of resisting substantial thermal expansion throughout the range of anticipated elevated temperatures. 15/32" Thick Wood Structural Panels, Min. This document is intended toaid in the design of various woodframe walls and w-ood - frame floor/ceiling assemblies, where such assemblies are required by code to be fire -resistance-rated. Roof-Ceiling Assemblies. See table below for possible assemblies relative to joist flange These wall assembly files are used for planning and estimation purposes for many UL wall types, such as fire-rated wall assemblies. supports for roof assemblies. It is a key differentiator for products within the exterior wall assembly market. The Numbering System for Fire-rated Assemblies table is a reference for the types of construction needed (e. The Fire Ratings table offers a quick reference summary of design numbers, fire ratings, deck type, SFRM Spray Applied Fire Resistive material listings and more. Layer 7 - Steel Framing Members: 1 layer Suspension System May be Used in Lieu of the Resilient Channels. Sometimes this is also called the assembly’s fire endurance. Roof Insulation-Foamed Plastic* — 36 by 48 in. The test methods are intended to help determine the uplift resistance of various roofing materials. Floor-Ceiling Assemblies. Mechanically Attached Metal Roof Panels 16″ wide – Type ZL standing seam panel system (24 MSG minimum gage coated steel) to be placed over specified insulations and/or %PDF-1. In addition, any compressible UL Classified glass fiber insulation with or without a vapor-retarder facing may be used between the specified roof insulation and metal roof. The fire resistance rating developed also applies to a Class A or Class B roofing material. g. Assemblies within our TJI® ICC-ES report ESR-1153; TJ-1500 - Fire-rated Assemblies and Sprinkler System Guide; Intertek listed assemblies ; I-joist assemblies within Table 721. “Ice and Water Shield”. , 2325 Lakeview Parkway, Suite 475, Alpharetta, GA 30009, USA Layer 2 - Roof Insulation: 1 layer Polyisocyanurate Insulation Boards, 1" Thickness Min. Staples having See UL directory for fire rated assemblies. This Standard outlines test methods for evaluating roof assemblies consisting of roof decking, or sheathing, and roof-covering materials. 9 Perimeter Fire Containment System - An assembly consisting of specific products or materials designed to resist the passage of fire through voids created at the intersection of exterior curtain wall assemblies and fire-resistance-rated floor or floor/ceiling assemblies for a prescribed period of time. Accordingly, Class A roof assemblies are suitable for use where Class A, Class B or Class C roofs are required, Find the right steel studs, limiting heights and spans, and fire-rated assemblies for your shaft walls. The UL Certification Mark on fire resistant products, systems and assemblies is relied on by code enforcement officials and buyers to provide confidence that products and systems meet regulatory and market requirements. 6 %âãÏÓ 105 0 obj > endobj 181 0 obj >/Filter/FlateDecode/ID[8B2D52539154B44186BE460602F09462>7978BB4823044DA4863AD9B8DDC38DE0>]/Index[105 4536]/Info 104 0 Fire Safety Building assembly’s The period of time the assembly will serve as a barrier to the spread of fire and how long fire resistance the assembly can function structurally after it is exposed to a fire of standard intensity as defined by CAN/ULC S101 and ASTM E119. Jul 9, 2021 · Q: For buildings without an accessible attic space, as in some townhouse or multifamily flat roof assemblies, Are there UL fire resistance rated roof-ceiling designs that can easily meet Grade I insulation quality standards? Oct 25, 2013 · IBC Section 1505 requires that roof assemblies meet the UL 790 Class A, B, or C fire performance based on the type of construction of the building on which they May 5, 2020 · Roofing System* — Any UL Class A, B or C Roofing System (TGFU) or Prepared Roof Covering (TFWZ) acceptable for use over nom 15/32 in. Roof Deck Table Notes: 1. Grade "C-D" or "Sheathing" Ply Sheet (Optional): — Any UL Classified Type G1, G2 or G3 base/ply sheet, Type 15, 20 or 30 felt or UL Classified prepared roofing accessory or GCP Applied Technologies Inc. ) Or search by the assembly number (UL design, or Gypsum Association file number) Then click on the Search button, and your results will be displayed below. 1(3) of the International Building Code; I-joist assemblies provided by Underwriters Laboratories (UL). , floor-ceiling, beams Roof-Ceiling Assemblies. Deck: NC | Incline: No Limitations | Impact: Class 4 VERCO UL ROOF | SEP 2023. com. View Sustainability Certifications: MK-6sProduct DescriptionMONOKOTE® MK-6 HY and MK-6s are single component, spray applied, mill-mixed fire resistive plasters. Floor-Ceiling Assemblies; Roof-Ceilings Assemblies; Design Details; Sheetrock® EcoSmart Gypsum Panel (UL Type ULIX™) Layer 9 - Gypsum Panel: 1 layer 5/8" [15. 2. VERCO ® ROOF DECK • Verco steel decks may be used in assemblies which are required to meet hourly fire. Surfacing: — Coated Steel or aluminum roofing panels, mechanically fastened. Approved hourly fire rated assemblies are a combination of specific. Helpful documents and resources for USG’s roof assemblies can be found on this page. Unless specifically described in a design, the addition of insulation in the concealed space between the UL D883 Restrained Assembly Ratings – 1, 1-1/2, 2 and 3 Hr Unrestrained Assembly Ratings – 1, 1-1/2 , 2 and 3 Hr Unrestrained Beam Ratings – 1, 1-1/2 , 2 and 3 Hr 1 layer Any UL Class A, B or C Roofing System (TGFU) or prepared Roof Covering (TFWZ) Layer 2 - Roof Sheathing: 1 layer Nom. Why UL Solutions for fire resistance testing. thick wood structural panels, min. Second, choose the type of design you are seeking (example – Walls/Partitions (steel framed), Floor/Ceiling (wood framed), etc. ratings. See Item 9 for min thicknesses with or without the use of gypsum wallboard (Item 13). Our range of drawings can help pros plan projects more effectively by utilizing designs for a fire-rated ceiling assembly. USE UL RECOGNIZED VERCO ROOF DECKS FOR YOUR FIRE RATED . with no limit on Max. The ratings relate to fire tests designed to determine how quickly fire can raise the temperature to unacceptable levels. giyd woe henxh lrvo siyn korify crlyqsh tpljue mtnc lnjj